Calibration management
Every measuring instrument calibrated, tagged, entered into a maintained register, and chased before it falls due.
PROGRAMMES / P-05
In detail
Calibration produces certificates. Certificates on their own do not tell you what is due, what is overdue, or what a measurement can actually be trusted to.
The register is the product
01 / 04Every instrument we calibrate goes into a single controlled register: asset identity, location, measurement parameter, working range, method and reference standard applied, calibration date, interval, next-due date, tolerance, measured deviation, uncertainty, verdict, and the certificate number that evidences all of it.
One sheet, traceable line by line to a source document. It is the artefact an auditor asks for, and producing it in ten seconds rather than ten days is most of the value of the programme.
- Asset identity
- ID, make, model, serial, location
- Measurement
- Parameter, working range, tolerance
- Method
- Reference method and standard applied
- Dates
- Calibrated, interval, next due
- Result
- Deviation, uncertainty, verdict
- Evidence
- Certificate number, cross-referenced
Nothing expires unnoticed
02 / 04We track the due dates on your behalf and write to your nominated contacts at sixty, thirty and seven days. The failure this prevents is mundane and extremely common: an instrument quietly passes its due date, production continues on it for weeks, and every measurement taken in that window is now questionable.
Out of tolerance
03 / 04Any instrument found outside its acceptance criteria is reported immediately with as-found data, so you can assess what was measured on it since the last calibration. Where it can be adjusted on site, it is adjusted and re-calibrated during the same visit at no additional charge. Replacement is quoted separately and only proceeds with your written approval.
As-found data matters more than as-left data. As-left tells you the instrument is fine now. As-found tells you what your last three months of readings were worth.
Term and rates
04 / 04Available as a single annual engagement or as a three-year programme. On the three-year term the rate is fixed for the full thirty-six months with no annual increase, new instruments are folded in at the same unit rates, and visits are planned around your production calendar rather than booked reactively.
At a glance
- Register
- Maintained, reissued each visit
- Reminders
- 60, 30 and 7 days before due
- Term
- One or three years
- Attendance
- On site, travel included